The front control panel of the updated Eppendorf 5402 features tactile knobs and digital displays designed for rapid parameter entry and real-time monitoring.
| Parameter | Value | |-----------|-------| | Max. speed | 14,000 rpm | | Max. RCF | 16,873 × g (with fixed-angle rotor F-45-30-11) | | Max. capacity | 30 × 1.5/2.0 mL tubes (fixed-angle) or 24 × 1.5/2.0 mL (swing-out) | | Timer | 0 – 30 min or continuous | | Dimensions (W×D×H) | 28 cm × 33 cm × 26 cm | | Weight | ~12 kg | | Noise level | < 60 dB(A) at max speed |
Clean the rotor chamber at the end of the day with a damp cloth and mild dish soap.
The Eppendorf 5402 centrifuge is a floor-standing, high-speed centrifuge that offers a wide range of applications, including molecular biology, microbiology, and clinical research. Its compact design and quiet operation make it an ideal choice for laboratories with limited space. The instrument features a high-contrast LCD display, intuitive navigation, and a broad range of pre-programmed protocols, allowing users to easily select and run various centrifugation programs. eppendorf 5402 manual updated
Sets the duration of the run. Turning the knob fully counter-clockwise or past 99 minutes engages the continuous "Hold" mode.
Press the button. If the unit is unpowered or locked, use the mechanical emergency release. Inspect the rotor chamber for debris. Load your balanced samples symmetrically into the rotor.
Press STOP immediately. Wait for standstill. Clean spilled liquids and re-balance tubes using a scale. Condenser coils blocked; lid seal leaking; low refrigerant. The front control panel of the updated Eppendorf
Insert the emergency release tool (or a small screwdriver) into the opening to manually trip the mechanical latch. 6. Service and Calibration Updates
Modern lab safety regulations require quick access to equipment instructions for all lab personnel.
This guide acts as a summary of typical operation. Always consult the specific, original manufacturer documentation for the most precise, up-to-date information for your unit. RCF | 16,873 × g (with fixed-angle rotor
Power down the unit. Vacuum dust and lint away from the ventilation grills. Ensure the unit has at least 6 inches of clearance from laboratory walls for proper airflow. If cooling fails entirely, contact an authorized service technician. Drive motor error or tachometer malfunction.
The most reliable source currently is , which hosts a 9-page instruction manual covering the 5402, the 5415 C micro-centrifuge, and the F-45-18-11 rotor. This document is the cornerstone for understanding the device. While other lab equipment forums like LabWrench may host user discussions and Q&A for the 5402, they explicitly state that no official manuals are available directly on their site.